Liquid ring vacuum pump installation
Besides, it would help if you made sure that there are no slings or hooks attached because they can also cause severe installation problems. Power It Up When Fully Assembled — After unpacking, most people think that pumps are ready to plug and use, but that is not the case.
Taking a test run can prove to be a severe problem. It would be best to start with the operation only when you install it entirely and set the proper liquid you wish to use.
You should check here to learn everything about converting tire inflator into a vacuum pump. Safely Store — You need to make sure to protect the unit by following particular tips and rules. For instance, you should store it in a place where the temperature is moderate. The worst thing that you can do is to place it somewhere where the temperature is fluctuation and can quickly drop below freezing because that could affect the sealant liquid.
Setting Up — Even though most of the units tend to ruin slowly and smoothly, you need to place them on stable and robust surfaces.
The best solutions include concrete mounts or floors. In case you have bought a small vacuum, you can also place it on a skid or floor. On the other hand, if you got a large one, you should place it on a concrete pad.
Align and Install the Sheaves — If you have a pump that is using V-belt, you should both align and install the sheaves before you decide to set the tension to the belt. Only when you finish with the alignment, you should place the belts over them into the grooves. Piping — You need to be sure that both joints and pipes are perfectly aligned and without stress.
Remember that in factory settings, these parts have to be tested at least a few times, but problems may happen during the shipping, which is something you should remember. Belt Tension — After you finish with the rest, you should check out the tension of belts and do it so at least once in a few hours after usage.
Ohio Medical partial recirculating, NFPA 99 compliant vacuum system consists of electric motor driven positive displacement non-pulsating liquid ring vacuum pumps, ASME vacuum receiver, electrical control system, and interconnection piping and wiring.
The components are modularly assembled to accommodate most existing doorways and designed for serviceability. The packaged unit is factory tested prior to shipment and warranted for a period of 30 months from date of shipment or 24 months from date of start-up. Pump suction accessories include an inlet check valve, isolation valve and inlet flexible connector. The pump discharge separator vents are manifolded, and a flexible connector is provided for job site installation to facilitate connection of vent piping to the exterior of the building.
The make-up water lines include a strainer, regulating valve, solenoid valve with manual priming valve and flexible connector. Liquid-ring pumps come with many accessories, supplied by the manufacturer or by other companies in the field.
An application's particular requirements, mode of operation, and type of control scheme dictate the necessity of various items. The following covers some of the more commonly used items. Isolation Valves separate the pump from the system whenever it is shut down for extended periods of time or for maintenance procedures.
Gate valves or full-port ball valves are recommended for minimizing pressure drops in lines that are 3 inches or above in size. Butterfly valves are a more economical choice. Inlet check valves prevent the gas and seal liquid from flowing back to the process when the pump is stopped. Swing-check, double flexible-seal, or equal-type valves must be installed horizontally.
Inlet vacuum relief valves protect the pump from cavitation. When the pump's suction pressure is below the setting of a vacuum-relief valve, the valve will open bleed in atmospheric air or process gas if connected back to the pump's discharge side. Most inexpensive vacuum-relief valves are based on atmospheric pressure and need to be calibrated periodically. Flexible connectors are used to connect for slight misalignments between a pump and a process, or if a minimal amount of expansion is anticipated.
Inlet vacuum control valves are used to control the system's vacuum level by bleeding in atmospheric air or process gas recirculated back from pump discharge.
Pneumatically operated diaphragms mounted on globe valves are required to achieve a fine degree of control. Inlet vacuum gases measure the pressure at a vacuum pump's inlet.
Normally, they are mounted directly ahead of pump suction. Seal liquid flow-control valves are used to control the seal liquid's flowrate to the pump. A globe valve is a commonly used design.
Compound pressure gases are used to indicate the pressure at the inlet connection of the seal liquid piping to the pump. Approximate flowrates can be established, by maintaining the pressure properly at the connection point.
Discharge separator tanks separate the seal liquid from the discharged gas stream coming out of pump. These separator tanks can be either mounted on the floor, mounted on a base plate with the pump and used for partial and total recovery systems , or supported by the discharge piping used on once-through systems.
Solenoid valves are used to automatically stop or start the flow of seal liquid to the pump. Circulating pumps recirculate the seal liquid in total recovery systems. The pumps are required when the pump operates for prolonged periods at high absolute suction pressures or when excessive pressure drops occur due to heat exchangers, piping and valves, or both.
Atmospheric air ejectors provide suction pressures lower than that the liquid-ring pumps are capable of when operating alone Figure 4. The ejectors may be added to a pump, to provide an inlet pressures as low as 3 torr. The operation of air ejectors is similar to that of steam ejectors. Atmospheric air or recycled gas from separator discharge is used as the motive force for compressing the process gas from the system's design pressure up to that of the inlet pressure of the liquid-ring pump.
To enhance pumping capacity above 30 torr, a motive air shut-off valve can be added. To achieve full pump capacity above 30 turF, a bypass can also be added. Like the proper installing of vacuum pumps, troubleshooting them is critical to their operation and maintenance. As a result, it is important that only qualified personnel, using proper equipment, be authorized to perform testing. There are many factors that can influence the performance of a vacuum system.
First, it is always good practice to inspect the equipment when it arrives at site, and then to make sure that the equipment is properly installed, and that all valves and flow switches are in correct direction as per the installation drawings. Verify that the pump rotates freely and in the proper direction, and that the system is properly primed before start-up. All these preliminary checks make troubleshooting of the system easier.
Malfunction of the vacuum system could be due to utility or process conditions, or both, or the equipment, and it is important to determine the cause. A malfunction due to external influences can be determined as follows:. The first step is o compare the original design conditions, especially gas composition and cooling water temperature to the existing condition.
Any change in the design conditions and the gas's composition may have an effect on the vacuum system. For example, an increase in the condensable load will raise the effective seal-liquid temperature and effect the vacuum system. A change in the condensable or non-condensable gas composition may effect the seal-liquid composition and the vacuum.
High seal-liquid temperatures will also affect the vacuum level. Make sure that there is no excessive air leakage. Back pressure on the system should be as per design conditions. Excessive back pressure increases the brake horsepower, and may have an effect on the capacity of the vacuum pump. If it is determined that the malfunction is not due to external influences, troubleshooting of the equipment can be made as follows:. Check the seal liquid's temperature rise across the pump.
This should be as per design. Even if cooling water temperature and gas composition meet design standards, a reduced seal could be due to a plugged strainer or partially closed value in the recirculation line. Also, check the recirculating pump's performance if furnished and the recirculating heat exchanger for any fouling. Any of these factors could have an effect on the performance of the vacuum system.
Check pump speed with a tachometer to make sure it meets design specifications. If the vacuum pump is V-belt driven, check the tension to ensure that the belts are not slipping.